Improving compressor efficiency is more than hot air

Aug. 26, 2013
How correcting compressed air inefficiencies saved one plant $500,000 a year.

Once problems were identified (see the first part of this case study), the project implementation plan included installing:

  • new dryers and mist-eliminating filters;
  • three pressure/flow controllers, one backpressure/flow controller and two 30,000-gal air storage tanks;
  • new piping and retrofits on existing portions of the piping system;
  • a programmable logic control (PLC) compressor automation system; and
  • a compressed-air management information system (MIS).

The facility also repaired compressors performing below optimum levels.

Once components were installed and repaired, the plant decided to reconfigure the four systems into one integrated system with three separate sections (high, medium and low pressure) with their own pressure levels.

Read the whole story on Chemical Processing

Sponsored Recommendations

Enclosure Climate Control: Achieving the Ideal Temperature

March 28, 2024
There are several factors to consider when optimizing the climate inside your electrical enclosure. Download this white paper to learn more.

Find the ideal enclosure cooling solution for your application

March 28, 2024
Use the Climate Control Quickfinder tool to find the ideal climate control solution for your application in just three easy steps.

Smart Cooling Solutions: Reduce Your Energy Consumption with Advanced Technology from Rittal

March 28, 2024
Wall extension cooling units for external or internal mounting in doors and walls using standardized mounting cut-outs. Cooling output 0.3 – 5.8 kW. Also available in energy-efficient...

Arc Flash Prevention: What You Need to Know

March 28, 2024
Download to learn: how an arc flash forms and common causes, safety recommendations to help prevent arc flash exposure (including the use of lockout tagout and energy isolating...