Compressed air: 7 common pitfalls in system design

Feb. 12, 2018

Failure to consider these items can greatly increase your operating costs.

I’ve seen a lot of pictures of brand-new compressed air installations proudly displayed on compressor-related social media sites by equipment suppliers. In looking at these through the eyes of an experienced energy-efficiency auditor, I am often quite disappointed, knowing the systems will provide adequate compressed air volume and quality but at higher energy cost to the customer than necessary.  I often wonder whether the equipment suppliers have tried to offer the more-efficient choices to the end user.

Of course, the blame often rests with the end user, who asks for and accepts the lowest-cost bid, not knowing that the purchase of a better compressor, dryer, filters and piping will reduce the operating costs for years to come and more than pay for any additional costs in a year or so. Energy is important to the life-cycle cost of the compressor and by far the most costly input – energy costs will greatly exceed the initial purchase cost of the compressor.

Here are some common pitfalls in replacing compressors:

  1. Reciprocating to screw conversion – When converting from a reciprocating compressor to a screw compressor, the customer will gain many benefits, but one of them is not usually energy efficiency, especially if a fixed-speed compressor is purchased and runs at low-duty cycle. Many customers are surprised to learn their new screw is consuming twice the previous energy consumed because of lack of storage receiver capacity and improper pressure set points.
  2. Fixed-speed instead of variable – Fixed-speed compressors are usually more efficient than screw compressors at full load, but if running at part loads, then the opposite is true, especially if the system has only one compressor. Most systems run at part loads for a significant length of time. Variable-speed-drive-controlled compressors, when installed in appropriate locations, will quickly pay for any additional cost in locations with variable-shift-oriented loads.
  3. Lack of storage capacity – Adding appropriate storage increases the installation cost, but the added capacity makes the system compressors run better. A receiver size of between 5 and 10 gallons of storage capacity for each cfm trim compressor output helps make the compressor much more efficient. Yes, I know that’s big, but so is the compressor power bill, if you add it up. And don’t forget to add a wet receiver before the dryer.
  4. Poor-efficiency dryers – Modern, energy-efficient air dryers have energy controls that can help save power over standard noncycling and fixed-cycle desiccant dryers. Consider cycling or dew-point-controlled dryers.
  5. Piping too small – Many installations use the same size piping in the compressor room as for the discharge of the compressor or will downsize if aluminum pipe is used. This leads to higher velocities in the pipeline, especially at direction changes, and excessive pressure loss. This loss causes the compressor to be less efficient and reduces the effective storage receiver capacity.
  6. Too many filters – Avoid overfiltering your compressed air. If most of your load is general-duty, with the odd end use that needs higher air quality, consider installing the extra filtering at the end use only. Too many filters adds pressure differential and reduces system efficiency.
  7. Pressure too high – If your system is running at greater than 100 psi, then you are running at less-than-optimum efficiency. Question why your system pressure is so high; often it is set by the compressor supplier. If it's an internal requirement for some reason, study your loads and find the cause of excess pressure requirements. Often it will be one or two items, such as low-cost connectors or undersized regulators that can be optimized. Then the compressor discharge pressure can be reduced.

Ron Marshall is a compressed air energy efficiency expert and a compressed air trainer with website at www.compressedairaudit.com

Join Ron at the Compressed Air Efficiency LinkedIn discussion group at https://www.linkedin.com/groups/12065406

About the Author

Ron Marshall

Ron Marshall first developed his skills as an industrial compressed air systems expert at Manitoba Hydro, where he worked for 38 years, supporting more than 600 energy efficiency projects. He now operates his own compressed air energy efficiency consulting firm where he provides technical advice, system auditing, and training.  Ron is a level 2 instructor with Compressed Air Challenge and conducts training internationally. Contact him at [email protected].Want to learn more about compressed air? We would suggest sending key staff to one of our Compressed Air Challenge seminars to help them learn what is possible. To learn more about upcoming training opportunities visit the CAC calendar at https://www.compressedairchallenge.org/calendar.

Sponsored Recommendations

Arc Flash Prevention: What You Need to Know

March 28, 2024
Download to learn: how an arc flash forms and common causes, safety recommendations to help prevent arc flash exposure (including the use of lockout tagout and energy isolating...

Reduce engineering time by 50%

March 28, 2024
Learn how smart value chain applications are made possible by moving from manually-intensive CAD-based drafting packages to modern CAE software.

Filter Monitoring with Rittal's Blue e Air Conditioner

March 28, 2024
Steve Sullivan, Training Supervisor for Rittal North America, provides an overview of the filter monitoring capabilities of the Blue e line of industrial air conditioners.

Limitations of MERV Ratings for Dust Collector Filters

Feb. 23, 2024
It can be complicated and confusing to select the safest and most efficient dust collector filters for your facility. For the HVAC industry, MERV ratings are king. But MERV ratings...