You don't have to break the bank to get a head start on auditing your compressed air system for efficiency.  For some systems you can get a good idea of how well your system is running by using hour meter data that is automatically collected by the air compressor controls.
If your air compressors are under load/unload control, finding and recording the loaded and running hours can tell you a lot about your system efficiency.  Say, for example, one of your compressors shows 3,000 hours loaded time and 10,000 hours run time.  This is a red flag that the compressor may be running inefficiently.  A ratio of loaded to running hours, in this case 30%, shows the compressor is lightly loaded and running unloaded 70% of the time.
A typical unloaded rotary screw compressor consumes between 20% and 40% of its full load power while running unloaded, even though it is producing no air. For the conditions just described about 45% of the total compressor energy consumption would be consumed in the unloaded condition.  Applying common efficiency measures, such as auto shutoff, start/stop, or VSD compressor control can correct this situation by reducing or eliminating unloaded run time.
But simply taking the ratio of the hours may not give you current conditions.  If you take the readings again  at the same time of day one week later, and subtract the previous numbers, you will end up with the average weekly duty cycle. If you multiply the ratio you calculate by the compressor rated cfm you will come out with a rough average flow from that compressor for the week. And if you know the full load and unloaded kW you can even approximate a specific power number, like a compressor gas mileage reading.  Compare this to the compressor's CAGI specification and you can see how far away you are from the ideal.
For example, if the compressor calculated above consumed 88 kW fully loaded and 31 kW unloaded at 30% duty cycle the average power consumed loaded would be 88 kW x .3 =  26.4 kW .  Unloaded power would consume 31 kW x .7 = 21.7 kW.  Total theroetical power would then be 26.4 + 21.7 = 48.1 kW.  If this compressor is rated at 440 cfm its average output would be 440 x .3 = 132 cfm.  Calculating the specific power would yield 48.1 / 132  x 100 = 36.4 kW per 100 cfm.  But this compressor at full load is rated at 88kW / 440 cfm x 100 = 20 kW/100 cfm.  The numbers suggest the compressor is consuming 80% more power than rated, an indication of inefficiency.  Of course if this compressor is a lubricated screw compressor installed with small storage capacity the real numbers might be significantly worse.
If you have multiple compressors this calculation can be repeated for each compressor and combined in to a complete system number.  These numbers can be tracked week by week by your maintenance staff.  Accuracy can vary, but this is a quick and dirty way to keep track of your basic system efficiency with simple tools like pencil, paper and a calculator.
If you want to learn more about basic auditing techniques go to this article about "auditing on a budget".
More information about compressed air efficiency can be found at the Compressed Air Challenge website.

Sponsored Recommendations

Arc Flash Prevention: What You Need to Know

March 28, 2024
Download to learn: how an arc flash forms and common causes, safety recommendations to help prevent arc flash exposure (including the use of lockout tagout and energy isolating...

Reduce engineering time by 50%

March 28, 2024
Learn how smart value chain applications are made possible by moving from manually-intensive CAD-based drafting packages to modern CAE software.

Filter Monitoring with Rittal's Blue e Air Conditioner

March 28, 2024
Steve Sullivan, Training Supervisor for Rittal North America, provides an overview of the filter monitoring capabilities of the Blue e line of industrial air conditioners.

Limitations of MERV Ratings for Dust Collector Filters

Feb. 23, 2024
It can be complicated and confusing to select the safest and most efficient dust collector filters for your facility. For the HVAC industry, MERV ratings are king. But MERV ratings...